IEC 60745-2-17:2010
IEC 60745-2-17:2010
Title | Hand-held motor-operated electric tools - Safety - Part 2-17: Particular requirements for routers and trimmers |
Abstract | IEC 60745-2-17:2010 Deals with the safety of routers and trimmers which the rated voltage is not more than 250 V for single-phase a.c. or d.c. tools, and 440 V for three-phase a.c. tools. Supplements or modifies the corresponding clauses of IEC 60745-1. This third edition cancels and replaces the second edition published in 2003, of which it constitutes a technical revision. Main changes include: Clause 8: Marking and instructions, addition of some router specific safety warnings, clarifications in Annex K, the addition of Annex M: Safety of working stands for operation with hand-held motor-operated electric tools, and editorial modifications to match with the fourth edition of IEC 60745-1. |
Issue Date | 2010-05-31 |
Category | TOOL |
Included in IECEE System | 2010-07-29 |
Purchase | webstore |
Test Report Form | |
Testing Equipment List | No information declared |
DISCLAIMER: National differences
The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.
Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Group/Country | Reference | Last Modified | Differences | TRF Addendum |
---|---|---|---|---|
Australia | AS/NZS 60745.2.17:2011 for use in conjunction with AS/NZS 60745.1:2009 | 2020-10-02 | Download112 kb | |
Australia | AS/NZS 60745.2.17:2011 | 2018-05-07 | Download58 kb | |
Canada | CAN/CSA-C22.2 No. 60745-2-17-11, Third Edition | 2014-10-26 | Download117 kb | |
CENELEC | EU_GD_IEC60745_2_17C | 2016-05-27 | Download56 kb | |
CENELEC | EN 60745-2-17:2010 | 2010-10-15 | Download74 kb | |
CENELEC | EN 60745-2-17:2010 used in conjunction with EN 60745-1:2009+A11:2010 | 2020-11-19 | Download56 kb | |
New Zealand | AS/NZS 60745.2.17:2011 for use in conjunction with AS/NZS 60745.1:2009 | 2020-10-02 | Download112 kb | |
United States of America | UL 745-2-17 | 2018-03-21 | Download23 kb |
Laboratory Name | City | Country | Responsible National Certification Body |
---|---|---|---|
CCIC-CSA International Certification Co. Ltd. Shanghai Branch | Shanghai | China | |
Shanghai | China | ||
94447 Plattling | Germany | ||
Toronto | Canada | ||
Guangzhou, | China | ||
Shanghai 200436 | China | ||
Dresden | Germany | ||
P.O. Box 67, Dubai | United Arab Emirates | ||
Eurofins Electric & Electronic Product Testing AG, Lab Fehraltorf | Fehraltorf | Switzerland | |
Shanghai | China | ||
Guangdong Testing Institute of Product Quality Supervision (GQI) | Guangzhou, | China | |
Kaufbeuren | Germany | ||
Kista | Sweden | ||
Shanghai | China | ||
Guangzhou, Guangdong | China | ||
Hangzhou 310018 | China | ||
Fontenay-Aux-Roses | France | ||
Shanghai | China | ||
Shanghai | China | ||
Helsinki | Finland | ||
Shanghai | China | ||
Ljubljana | Slovenia | ||
Hartmannsdorf | Germany | ||
Guangdong Province | China | ||
Xiaoshan | China | ||
Shanghai | China | ||
Shanghai | China | ||
Budapest | Hungary | ||
Nürnberg | Germany | ||
Taoyuan City 333 | Chinese Taipei | ||
Ningbo | China | ||
Jiangsu | China | ||
TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch | Shanghai | China | |
Frankfurt | Germany | ||
Fremont, | United States of America | ||
Northbrook, IL 60062 | United States of America | ||
Research Triangle Park | United States of America | ||
Offenbach / Main | Germany |
Id | Name | City | Country |
---|---|---|---|
13336 | Toronto, Ontario | Canada | |
13338 | Beijing 100070 | China | |
13360 | Arnhem | Netherlands | |
13372 | Fehraltorf | Switzerland | |
13348 | Reichenwalde b. Berlin | Germany | |
13371 | Kista | Sweden | |
13365 | Singapore | Singapore | |
13343 | Fontenay-Aux-Roses | France | |
13761 | P.O. Box 6122, Dubai | United Arab Emirates | |
13843 | Hamburg | Germany | |
13334 | BRUSSELS 1070 | Belgium | |
13342 | Helsinki | Finland | |
13367 | Ljubljana | Slovenia | |
13347 | Hartmannsdorf | Germany | |
13349 | Budapest | Hungary | |
13345 | Nürnberg | Germany | |
13427 | Singapore 609937 | Singapore | |
13346 | München | Germany | |
13423 | Northbrook | United States of America | |
13344 | Offenbach / Main | Germany |
Id | Name | City | Country |
---|---|---|---|
13721 | BELLIS Testing and Certification of Home Appliances and Industrial Products JSC | Minsk | Belarus |
13607 | Baltimore, | United States of America | |
13603 | Moscow | Russian Federation |