IEC 60730-2-22:2014 applies to the partial evaluation of thermal motor protectors as defined in IEC 60730-1 for household and similar use, including heating, air conditioning and similar applications as well as for sealed (hermetic and semi-hermetic type) motor-compressors. A thermal motor protector is considered an integrated control since its protective functionality is dependent on the correct mounting and fixing in or on a motor and which can only be fully tested in combination with the relevant motor. This dependency is illustrated by:
- the ability of the thermal motor protector to accurately and reliably sense the heat of the motor windings;
- thus, addressing the over-temperature protection due to motor overload conditions;
- the ability of the thermal motor protector to accurately and reliably sense the current due to motor locked-rotor conditions;
- thus, reducing the response time and not being adversely affected by heat-sink at the assembly spot in the application and the influence of the motor's electromagnetic field on the switch behaviour of the thermal motor protector;
- particularly, affecting the arc direction between the contacts resulting in uneven wear of the contact material and eventually leading to failure of operation. Requirements concerning the testing of the combination of sealed (hermetic and semi-hermetic type) motor-compressors and thermal motor protectors are given in IEC 60335-2-34. This standard applies to thermal motor protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Key words: Thermal, Motor protectors, Integrated control

This publication is to be read in conjunction with IEC 60730-1:2010.

Issue Date

2014-05-13

Category

CONT

Included in IECEE System

2014-07-07

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

United States of AmericaUnited States of America

2023-07-06

Download62 kb

United States of AmericaUnited States of America

2019-06-20

Download131 kb

Id

Name

City

Country

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13371

Kista

Sweden

13424

IL 60005

United States of America

13349

Budapest

Hungary

13345

Nürnberg

Germany

13340

Ballerup

Denmark

13423

Northbrook

United States of America

13344

Offenbach / Main

Germany

No information declared