IEC 60335-2-48:2021

Title
Abstract

IEC 603352-48:2021 deals with the safety of electrically operated commercial grillers and toasters , their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances.
Rotary or continuous grillers or toasters and similar appliances intended for grilling by radiant heat such as rotisseries, salamanders, etc., are within the scope of this standard. These appliances are not intended for household and similar purposes. They are used for commercial processing of food, also in areas open to the public, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries and butcheries. The electrical part of appliances making use of other forms of energy is also within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by these types of appliances.
Attention is drawn to the fact that:
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
– in many countries additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities;
– for appliances intended to be used outdoors, additional requirements can be necessary.
This standard does not apply to:
– appliances designed exclusively for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– appliances for continuous mass production of food;
– commercial electric griddles and griddle grills (IEC 60335-2-38);
– battery-operated appliances;
– grills, toasters and similar portable cooking appliances for household use covered by IEC 60335-2-9 and used in the following environments by laymen: staff kitchen areas in shops, offices and other working environments, farm houses, hotels, motels and other residential type environments, bed and breakfast type environments.
This fifth edition cancels and replaces the fourth edition published in 2002, Amendment 1:2008 and Amendment 2:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) some notes have been converted to normative text, modified or deleted (Clause 1, 7.15, 9.101, 11.7, 22.101, 23.3, 27.2, 30.101);
c) clarifications to some test specifications have been made (7.101, 11.4, 15.1.1, 19, 20.1, 25.3);
d) introduction of requirements for appliances intended for use in areas open to the public, including external accessible surface temperatures (Clause 1, 7.12, 11.8, Table 102);
e) clarification of applicable standard for appliances for use by laymen (Clause 1, 7.12);
f) exclusion of battery-operated appliances;
g) relocation of cleaning instructions from 7.12.1 to 7.12;
h) relocation of 24.101 to 22.104;
i) additional instructional requirements in 7.12;
j) conciliation of the text of IEC 60335-2-48 with other standards under IEC/TC61/MT32.
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

Issue Date

2021-11-03

Category

HOUS

Included in IECEE System

2021-11-08

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

No information declared

Laboratory Name

City

Country

Responsible National Certification Body

Istanbul

Türkiye

Beijing

China

Guangzhou,

China

Arnhem

Netherlands

Shanghai 200436

China

Guangzhou

China

Guangdong

China

Guangzhou

China

Milano

Italy

San Vendemiano (Treviso)

Italy

Arlington Heights

United States of America

Kaufbeuren

Germany

New Delhi

India

Campoformido (UD)

Italy

Plano,

United States of America

Kista

Sweden

Shanghai

China

Kowloon

Hong Kong

Guangzhou, Guangdong

China

Shenzhen City, Guangdong Province

China

Guangzhou

China

Biassono (MB)

Italy

Madrid

Spain

Shanghai

China

Guangzhou

China

Ningbo

China

Volpiano (TO)

Italy

Budapest

Hungary

München

Germany

20061 Carugate (MI)

Italy

Id

Name

City

Country

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13351

Milano

Italy

13371

Kista

Sweden

13365

Singapore

Singapore

13749

NL - 7327 AC Apeldoorn

Netherlands

13356

Gyeongsangnam-do

Korea, Republic of

13361

Lysaker

Norway

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13349

Budapest

Hungary

13346

München

Germany

13340

Ballerup

Denmark

Id

Name

City

Country

13345

Nürnberg

Germany