IEC 60335-2-44:2021 deals with the safety of electric ironers for both commercial and household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. Appliances not intended for normal household, but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. Examples of appliances within the scope of this standard are:
– ironing presses for one-person operation;
– mangles;
– rotary ironers for one-person operation;
– trouser presses.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account:
– persons (including children) whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
– children playing with the appliance.
Attention is drawn to the fact that:
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
– in many countries additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to:
– rotary ironers for operation by more than one person. The roller length of such appliances normally exceeds 1,6 m in length;
– appliances intended exclusively for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– electric irons (IEC 60335-2-3);
– battery-operated appliances.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2008 and Amendment 2:2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) some notes have been converted to normative text (1, 20.1, 22.103);
c) exclusion of battery-operated appliances (Clause 1);
d) introduction of accessible surface temperature limits (Clause 11).
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

Issue Date

2021-11-03

Category

HOUS

Included in IECEE System

2021-11-08

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

AustraliaAustralia

2024-06-02

Download109 kb

AustraliaAustralia

2024-10-03

Download68 kb

CanadaCanada

2023-05-10

Download57 kb

New ZealandNew Zealand

2024-10-03

Download68 kb

New ZealandNew Zealand

2024-04-13

Download109 kb

United Arab EmiratesUnited Arab Emirates

2024-06-24

Download60 kb

Laboratory Name

City

Country

Responsible National Certification Body

Shenyang, Liaoning

China

Guangzhou,

China

Arnhem

Netherlands

Foshan

China

Kaufbeuren

Germany

Plano,

United States of America

Shanghai

China

Kowloon

Hong Kong

Guangzhou, Guangdong

China

Haining City

China

Padova

Italy

Lysaker

Norway

Shanghai

China

Guangzhou

China

Ningbo

China

Shunde District,

China

Guangzhou

China

Shanghai

China

Budapest

Hungary

Frankfurt

Germany

München

Germany

Shatin, N.T.

Hong Kong

North Carolina

United States of America

Offenbach / Main

Germany

Id

Name

City

Country

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13371

Kista

Sweden

13365

Singapore

Singapore

13749

NL - 7327 AC Apeldoorn

Netherlands

13361

Lysaker

Norway

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13349

Budapest

Hungary

13354

Yokohama

Japan

13346

München

Germany

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany

Id

Name

City

Country

13336

Toronto, Ontario

Canada

13761

P.O. Box 6122, Dubai

United Arab Emirates