IEC 60335-2-41:2024 deals with the safety of electric pumps for liquids having a temperature not exceeding 90 °C, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including direct current (DC) supplied appliances and battery-operated appliances. Examples of appliances within the scope of this standard are
- aquarium pumps;
- garden pond pumps;
- shower-boost pumps;
- sludge pumps;
- submersible pumps;
- table fountain pumps;
- vertical wet pit pumps.
Appliances not intended for normal household use, but that nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by ap-pliances that are encountered by all persons in and around the home. However, in gen-eral, it does not take into account
- persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
- children playing with the appliance.
Attention is drawn to the fact that
- for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
- in many countries additional requirements are specified by the national health authori-ties, the national authorities responsible for the protection of labour and similar au-thorities.
This standard does not apply to
- stationary circulation pumps for heating and service water installations (IEC 60335-2-51);
- pumps for flammable liquids;
- pumps intended exclusively for industrial purposes;
- pumps intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- pumps incorporating chlorinators of the electrolytic type.
Pumps incorporated in appliances are not covered by this standard unless a specific ref-erence is made.
This fifth edition cancels and replaces the fourth edition published in 2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with IEC 60335-1:2020;
b) modification or conversion of some notes to normative text (Clause 1, 7.12.1, 25.7);
c) introduction of IEC 60417 symbol for maximum operating depth and indoor use only (7.1, 7.6, 7.12.1);
d) clarification of requirements for aquarium pumps and garden pond pumps;
e) addition of legibility requirements for markings exposed to solar radiation (7.14);
f) clarification of pumps subjected to test probe 18 (8.1.1, 20.2);
g) introduction of accessible surface temperature limits (Clause 11);
h) addition of requirements for IEC 61984 connectors for pumps intended for permanent connection to fixed wiring (22.107, 24.1.5, 24.1.101, 25.3).
i) clarifications on remote operation for pumps in scope of this standard (22.40, 22.49, 22,51).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

Issue Date

2024-01-30

Category

HOUS

Included in IECEE System

2024-02-09

Purchase webstore
Test Report Form
Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

United Arab EmiratesUnited Arab Emirates

2024-06-24

Download60 kb

Laboratory Name

City

Country

Responsible National Certification Body

Arnhem

Netherlands

Shanghai 200436

China

Guangzhou

China

Osnago (LC)

Italy

New Delhi

India

Shanghai

China

Bangkok 10800

Thailand

Kowloon

Hong Kong

Guangzhou, Guangdong

China

Hangzhou 310018

China

Bangkok 10510

Thailand

Guangzhou

China

Shanghai

China

Guangzhou

China

Wien

Austria

Bearley, Stratford-upon-Avon, Warwickshire

United Kingdom

Volpiano (TO)

Italy

Budapest

Hungary

Pogliano Milanese

Italy

San Diego

United States of America

Shenzhen, Guangdong

China

Seoul 07326

Korea, Republic of

Frankfurt

Germany

München

Germany

Offenbach / Main

Germany

Id

Name

City

Country

13360

Arnhem

Netherlands

13371

Kista

Sweden

13365

Singapore

Singapore

13749

NL - 7327 AC Apeldoorn

Netherlands

13332

Vienna

Austria

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13349

Budapest

Hungary

13345

Nürnberg

Germany

13427

Singapore 609937

Singapore

13346

München

Germany

13344

Offenbach / Main

Germany

Id

Name

City

Country

13348

Reichenwalde b. Berlin

Germany

13761

P.O. Box 6122, Dubai

United Arab Emirates