IEC 60335-2-115:2021

Title
Abstract

IEC 60335-2-115:2021 deals with the safety of electric appliances for skin beauty care of persons and intended for household, commercial and similar purposes, their rated voltage being not more than 250 V.
Dual supply appliances, either mains-supplied or battery-operated, are regarded as battery-operated appliances when operated in the battery mode.
Examples of appliances that are within the scope of this standard are
– battery-operated appliances and other DC supplied appliances for beauty care;
– appliances with high frequency outputs including equipment for heat-producing effects on the skin;
– appliances with medium frequency outputs including interferential outputs, for skin stimulation or muscle stimulation;
– appliances with low frequency outputs (e.g. faradic currents) for application such as skin stimulation or muscle stimulation;
– appliances with extra-low voltage DC outputs (e.g. galvanic currents), such as electro-epilation (hair removal);
– skin beauty care appliances with ultrasonic outputs;
– appliances having vacuum-pressure functions;
– skin beauty care appliances for melting wax;
– appliances intended to produce surface cooling effect on the skin;
– facial cleaning appliances;
– micro-needling appliances;
– plasma pens.
Appliances covered by this standard can incorporate vapour-producing devices or spray-producing devices.
This standard deals with the common hazards presented by appliances that are encountered by all persons. However, in general, it does not take into account
– persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
– children playing with the appliance.
Attention is drawn to the fact that
– it is recognized that persons having very extensive and complex disabilities can have needs beyond the level addressed in this standard.
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements can be specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
– appliances intended exclusively for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– shavers, hair clippers and similar appliances (IEC 60335-2-8);
– blankets, pads, clothing and similar flexible heating appliances (IEC 60335-2-17);
– appliances for skin or hair care such as facial saunas, hand dryers, foot care appliances (IEC 60335-2-23);
– spray tanning appliances;
– appliances for skin exposure to optical radiation (IEC 60335-2-27);
– sauna heating appliances and infrared cabins (IEC 60335-2-53);
– cosmetic and beauty care appliances incorporating lasers and intense light sources (IEC 60335-2-113);
– appliances intended for medical purposes (IEC 60601);
– radio frequency appliances without contact to the skin;
– ultrasound appliances provided with focusing ultrasound transducers.
This part 2 is to be used in conjunction with the fifth edition of IEC 60335-1:2010 and its amendments.
The contents of the corrigendum of April 2022 have been included in this copy.

Issue Date

2021-03-11

Category

HOUS

Included in IECEE System

2022-06-03

Purchase webstore
Test Report Form
Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

AustraliaAustralia

2023-11-09

Download178 kb

CENELECCENELEC

2024-09-10

Download304 kb

New ZealandNew Zealand

2023-11-09

Download178 kb

New ZealandNew Zealand

2023-01-10

Download113 kb

Id

Name

City

Country

13348

Reichenwalde b. Berlin

Germany

13371

Kista

Sweden

13365

Singapore

Singapore

13761

P.O. Box 6122, Dubai

United Arab Emirates

13361

Lysaker

Norway

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13427

Singapore 609937

Singapore

Id

Name

City

Country

13354

Yokohama

Japan

13344

Offenbach / Main

Germany