Copeland Climate Technologies (Xi’An) Co., Ltd.
Copeland Climate Technologies (Xi’An) Co., Ltd.
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2024-04-19 |
Further information
Stage | Country | Name |
---|---|---|
2 | Denmark |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
CONT | IEC 60730-1:2013 | 9.3 Adequacy of earth connections10.2.4.3 Push/pull test for tabs12.2 Protection against humid conditions13.2 Electric strength14 Heating16.2 Environmental stress of temperature17 Endurance22.1 Resistance to corrosion24.4.1 Overload tests for switch mode power supplies25.2 Overvoltage and undervoltage testH.8 Protection against electric shockH.17.1.4.2 Thermal cycling testH.26.5 Voltage dips, voltage interruptions and voltage variations in the power supply networkH.26.8 Surge immunity testH.26.9 Electrical fast transient/burst immunity testH.26.10 Ring wave immunity testH.26.11 Electrostatic discharge testH.26.13 Test of influence of supply frequency variationsH.26.15 Evaluation of complianceH.27.1.1 Abnormal operationH.27.1.1.3, H.27.1.1.4 Electronic circuit faults | 2024-04-19 | |
CONT | IEC 60730-1:2013/AMD1:2015 | 9.3 Adequacy of earth connections10.2.4.3 Push/pull test for tabs12.2 Protection against humid conditions13.2 Electric strength14 Heating16.2 Environmental stress of temperature17 Endurance22.1 Resistance to corrosion24.4.1 Overload tests for switch mode power supplies25.2 Overvoltage and undervoltage testH.8 Protection against electric shockH.17.1.4.2 Thermal cycling testH.26.5 Voltage dips, voltage interruptions and voltage variations in the power supply networkH.26.8 Surge immunity testH.26.9 Electrical fast transient/burst immunity testH.26.10 Ring wave immunity testH.26.11 Electrostatic discharge testH.26.13 Test of influence of supply frequency variationsH.26.15 Evaluation of complianceH.27.1.1 Abnormal operationH.27.1.1.3, H.27.1.1.4 Electronic circuit faults | 2024-04-19 | |
CONT | IEC 60730-1:2013/AMD2:2020 | 9.3 Adequacy of earth connections10.2.4.3 Push/pull test for tabs12.2 Protection against humid conditions13.2 Electric strength14 Heating16.2 Environmental stress of temperature17 Endurance22.1 Resistance to corrosion24.4.1 Overload tests for switch mode power supplies25.2 Overvoltage and undervoltage testH.8 Protection against electric shockH.17.1.4.2 Thermal cycling testH.26.5 Voltage dips, voltage interruptions and voltage variations in the power supply networkH.26.8 Surge immunity testH.26.9 Electrical fast transient/burst immunity testH.26.10 Ring wave immunity testH.26.11 Electrostatic discharge testH.26.13 Test of influence of supply frequency variationsH.26.15 Evaluation of complianceH.27.1.1 Abnormal operationH.27.1.1.3, H.27.1.1.4 Electronic circuit faults | 2024-04-19 |