Vitzro EM
Vitzro EM
Address(es) |
|
Website | Not available |
Status | WITHDRAWN |
Acceptance date | 2022-01-12 |
Further information
Stage | Country | Name |
---|---|---|
2 | Denmark |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
POW | IEC 60947-1:2007 | 7.1.2.2 Glow wire testing7.1.4 Clearances and creepage distances7.1.12 Degrees of protection of enclosed equipment (IP 20) | 2021-11-23 | |
POW | IEC 60947-1:2007/AMD1:2010 | 7.1.2.2 Glow wire testing7.1.4 Clearances and creepage distances7.1.12 Degrees of protection of enclosed equipment (IP 20) | 2021-11-23 | |
POW | IEC 60947-1:2007/AMD2:2014 | 7.1.2.2 Glow wire testing7.1.4 Clearances and creepage distances7.1.12 Degrees of protection of enclosed equipment (IP 20) | 2021-11-23 | |
POW | IEC 60947-2:2016 | 8.3.3.2 Tripping limits and characteristics8.3.3.3 Dielectric properties8.3.3.4 Mechanical operation and operational performance capability (less than 690V, AC 1000A)8.3.3.5 Overload performance(less than 690V, AC 1000A)8.3.3.6 - 8.3.4.4 - 8.3.5.4 - 8.3.6.6 - 8.3.7.4 - 8.3.7.8 - 8.3.8.6 Dielectric withstand8.3.3.7 - 8.3.4.5 - 8.3.6.4 - 8.3.7.3 - 8.3.8.7 Temperature-rise (verification)8.3.3.8 - 8.3.4.5 - 8.3.5.2 - 8.3.5.5 - 8.3.6.2 - 8.3.6.7 - 8.3.7.5 - 8.3.7.9 - 8.3.8.2 - 8.3.8.8 Overload releases (verification)8.3.3.9 Verification of undervoltage and shunt releases 8.3.3.10 Verification of main contact positionAnnex B I | 2021-11-23 |