Unified Compliance Laboratory

Address(es)
  • 428 W 12800 So
    Draper 84020
    Utah
    United States of America
    385-200-1617
Website Not available
Status

WITHDRAWN

Acceptance date 2021-10-07

Further information

Stage

Country

Name

2

Norway

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

Accepted clauses…:5.2 (Energy Source Classification)5.4.1.4, 6.3.2, 9.0, B.2.6 (Maximum Operating Temperature)5.4.1.10.3 (Ball Pressure Test)5.4.2.2, 5.4.2.4, 5.4.3, Annex O (Creepage & Clearance)5.7.2.2, 5.7.4 (Touch Current)5.4.9 (Withstand Test)5.5.2.2 (Stored Discharge Test)5.6.6.2 (Resistance of Earth Connection)6.2.2 (Power source circuit classifications)8.5 (Safeguards against moving parts)8.6 (Stability)8.7 (Equipment mounted to a wall, ceiling or other structure)8.8 (Handle strength)8.9 (Wheels or casters attachment requirements)8.10 (Carts, stands, and similar carriers)Annex B.2.5 (Input Tests)Annex B.3 (Abnormal Operation Test)Annex B.4 (Fault Condition Test)Annex F.3.9 (Durability, legibility and permanence of markings)Annex P (Safeguards against conductive objects)Annex Q(Circuits intended for interconnection with building wiring)Annex T.2, T.3, T.4 & T.5 (Steady Force Test)Annex T.6 (Impact test)Annex T.7 (Drop Test)Annex T.8 (Stress Relief Test)Annex M.3, M.4, M.5, M.6 (Battery Test)Annex V (Determination of accessible parts)Annex Y.5 (Protection of equipment within an outdoor enclosure)
2021-10-07

OFF

Accepted clauses…:Clause 1.6.2 (Input Current)Clause 2.1 (Shock & Energy Protection)Clause 2.1.1.7 (Primary Cap Discharge)Clause 2.4 (Limited Current)Clause 2.5 (Limited Power)Clause 2.6.3 (Earth Continuity)Clause 4.1 (Stability)Clause 4.2 (Steady Force Test, 10N)Clause 4.3 (Steady Force Test, 30N)Clause 4.4 (Steady Force Test, 250N)Clause 4.2.5 (Impact Test)Clause 4.2.11 (Slide/rails)Clause 4.3.1 (Sharp Edges)Clause 4.3.2 (Knob Pull/Handle)Clause 4.5 (Heating)Clause 4.5.2 (Thermoplastics)Clause 4.6 (Openings in Enclosure)Clause 5.1 (Touch Current & PE Currents)Clause 5.2 (Electric Strength)Clause 5.3.4 (Functional Insulation)Clause 5.3.5 (Electro-Mechanical)Clause 5.3.7 (General Simulation of Faults)
2021-10-07

OFF

Accepted clauses…:Clause 1.6.2 (Input Current)Clause 2.1 (Shock & Energy Protection)Clause 2.1.1.7 (Primary Cap Discharge)Clause 2.4 (Limited Current)Clause 2.5 (Limited Power)Clause 2.6.3 (Earth Continuity)Clause 4.1 (Stability)Clause 4.2 (Steady Force Test, 10N)Clause 4.3 (Steady Force Test, 30N)Clause 4.4 (Steady Force Test, 250N)Clause 4.2.5 (Impact Test)Clause 4.2.11 (Slide/rails)Clause 4.3.1 (Sharp Edges)Clause 4.3.2 (Knob Pull/Handle)Clause 4.5 (Heating)Clause 4.5.2 (Thermoplastics)Clause 4.6 (Openings in Enclosure)Clause 5.1 (Touch Current & PE Currents)Clause 5.2 (Electric Strength)Clause 5.3.4 (Functional Insulation)Clause 5.3.5 (Electro-Mechanical)Clause 5.3.7 (General Simulation of Faults)
2021-10-07

OFF

Accepted clauses…:Clause 1.6.2 (Input Current)Clause 2.1 (Shock & Energy Protection)Clause 2.1.1.7 (Primary Cap Discharge)Clause 2.4 (Limited Current)Clause 2.5 (Limited Power)Clause 2.6.3 (Earth Continuity)Clause 4.1 (Stability)Clause 4.2 (Steady Force Test, 10N)Clause 4.3 (Steady Force Test, 30N)Clause 4.4 (Steady Force Test, 250N)Clause 4.2.5 (Impact Test)Clause 4.2.11 (Slide/rails)Clause 4.3.1 (Sharp Edges)Clause 4.3.2 (Knob Pull/Handle)Clause 4.5 (Heating)Clause 4.5.2 (Thermoplastics)Clause 4.6 (Openings in Enclosure)Clause 5.1 (Touch Current & PE Currents)Clause 5.2 (Electric Strength)Clause 5.3.4 (Functional Insulation)Clause 5.3.5 (Electro-Mechanical)Clause 5.3.7 (General Simulation of Faults)
2021-10-07