Pacific Kitchen Appliance Co Ltd
Pacific Kitchen Appliance Co Ltd
Address(es) |
|
Website | Not available |
Status | WITHDRAWN |
Acceptance date | 2018-08-15 |
Further information
Stage | Country | Name |
---|---|---|
2 | Denmark |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
HOUS | IEC 60335-1:2010 | Accepted clauses: 7.14 - Permanence of Marking TestAccepted clauses: 10.1, 10.2 - Power Input And Current TestAccepted clauses: 11.1, 11.3, 11.6 - HeatingAccepted clauses: 13.1, 13.2 - Leakage Current at Operating Temperature TestAccepted clauses: 15.3 - Moisture Resistance - Humidity TestAccepted clauses: 16.2 - Leakage Current after Humidity Test, 16.3 - Electric Strength after Humidity TestAccepted clauses: 17 - Overload Protection of Transformers and Associated Circuits TestAccepted clauses: 19.1, 19.2, 19.3, 19.4, 19.7, 19.11.1, 19.11.2, 19.12, 19.13, 19.14 - Abnormal Operation (Under Voltage & Restricted Heat Dissipation) TestAccepted clauses: 22.5 - Capacitor Discharge TestAccepted clauses: 23.5 - Internal Wiring Insulation Electric Strength TestAccepted clauses: 24.5 - Capacitor In Series with Auxiliary Winding of Motor Rating Verification TestAccepted clauses: 27.5 - Earthing Impedance Test | 2019-09-06 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | Accepted clauses: 7.14 - Permanence of Marking TestAccepted clauses: 10.1, 10.2 - Power Input And Current TestAccepted clauses: 11.1, 11.3, 11.6 - HeatingAccepted clauses: 13.1, 13.2 - Leakage Current at Operating Temperature TestAccepted clauses: 15.3 - Moisture Resistance - Humidity TestAccepted clauses: 16.2 - Leakage Current after Humidity Test, 16.3 - Electric Strength after Humidity TestAccepted clauses: 17 - Overload Protection of Transformers and Associated Circuits TestAccepted clauses: 19.1, 19.2, 19.3, 19.4, 19.7, 19.11.1, 19.11.2, 19.12, 19.13, 19.14 - Abnormal Operation (Under Voltage & Restricted Heat Dissipation) TestAccepted clauses: 22.5 - Capacitor Discharge TestAccepted clauses: 23.5 - Internal Wiring Insulation Electric Strength TestAccepted clauses: 24.5 - Capacitor In Series with Auxiliary Winding of Motor Rating Verification TestAccepted clauses: 27.5 - Earthing Impedance Test | 2019-09-06 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | Accepted clauses: 7.14 - Permanence of Marking TestAccepted clauses: 10.1, 10.2 - Power Input And Current TestAccepted clauses: 11.1, 11.3, 11.6 - HeatingAccepted clauses: 13.1, 13.2 - Leakage Current at Operating Temperature TestAccepted clauses: 15.3 - Moisture Resistance - Humidity TestAccepted clauses: 16.2 - Leakage Current after Humidity Test, 16.3 - Electric Strength after Humidity TestAccepted clauses: 17 - Overload Protection of Transformers and Associated Circuits TestAccepted clauses: 19.1, 19.2, 19.3, 19.4, 19.7, 19.11.1, 19.11.2, 19.12, 19.13, 19.14 - Abnormal Operation (Under Voltage & Restricted Heat Dissipation) TestAccepted clauses: 22.5 - Capacitor Discharge TestAccepted clauses: 23.5 - Internal Wiring Insulation Electric Strength TestAccepted clauses: 24.5 - Capacitor In Series with Auxiliary Winding of Motor Rating Verification TestAccepted clauses: 27.5 - Earthing Impedance Test | 2019-09-06 | |
HOUS | IEC 60335-2-31:2012 | Accepted clauses: 11.2, 11.7, 11.8 - HeatingAccepted clauses: 13.3 - Electric Strength (at Operation Temperature)Accepted clauses: 15.1, 15.2 - Spill/OverflowAccepted clauses: 19.1, 19.13, 19.101 - Abnormal Operation Test | 2019-09-06 | |
HOUS | IEC 60335-2-31:2012/AMD1:2016 | Accepted clauses: 11.2, 11.7, 11.8 - HeatingAccepted clauses: 13.3 - Electric Strength (at Operation Temperature)Accepted clauses: 15.1, 15.2 - Spill/OverflowAccepted clauses: 19.1, 19.13, 19.101 - Abnormal Operation Test | 2019-09-06 | |
HOUS | IEC 60335-2-31:2012/AMD2:2018 | Accepted clauses: 11.2, 11.7, 11.8 - HeatingAccepted clauses: 13.3 - Electric Strength (at Operation Temperature)Accepted clauses: 15.1, 15.2 - Spill/OverflowAccepted clauses: 19.1, 19.13, 19.101 - Abnormal Operation Test | 2022-04-28 |