nnuks Lighting (Shanghai) Co., Ltd. Test center
nnuks Lighting (Shanghai) Co., Ltd. Test center
Address(es) |
|
Website | Not available |
Status | WITHDRAWN |
Acceptance date | 2020-03-06 |
Further information
Stage | Country | Name |
---|---|---|
2 | Sweden |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
EMC | CISPR 15:2018 | Accepted clausesDisturbance voltages: clause 4.3 & 4.4Radiated electromagnetic disturbances(30MHz~300MHz): clause 4.5.3 | 2021-05-13 | |
EMC | CISPR 15:2013 | Accepted clauses Disturbance voltages: clause 4.3Radiated electromagnetic disturbances(30MHz~300MHz): clause 4.4.2 | 2021-05-13 | |
EMC | CISPR 15:2013/AMD1:2015 | Accepted clauses Disturbance voltages: clause 4.3Radiated electromagnetic disturbances(30MHz~300MHz): clause 4.4.2 | 2021-05-13 | |
EMC | IEC 61000-3-2:2018 | All | 2020-03-10 | |
EMC | IEC 61000-3-2:2018/AMD1:2020 | All clauses | 2021-05-19 | |
EMC | IEC 61000-3-3:2013 | All clauses (except for three phase) | 2021-05-13 | |
EMC | IEC 61000-3-3:2013/AMD1:2017 | All clauses (except for three phase) | 2021-05-13 | |
EMC | IEC 61547:2020 | Accepted clauses:Electrical fast transient/burst immunity test: clause 5.5Surge immunity test: clause 5.7Voltage dips and short interruptions: clause 5.8 | 2021-05-19 | |
EMC | IEC 61547:2009 | Accepted clauses:Electrical fast transient/burst immunity test: clause 5.5Surge immunity test: clause 5.7Voltage dips and short interruptions: clause 5.8 | 2020-03-10 | |
LITE | IEC 60598-1:2020 | Accepted clauses:Impact test: clause 4.13.1Mechanical suspensions fixing and connections: clause 4.14.1Adjusting devices test: clause 4.14.3Earth continuity test clause 7.2.3Resistance to moisture: clause 9.2Insulation resistance: clause 10.2.1Electric strength clause 10.2.2Touch current: clause 10.3Thermal test clause 12.4Glow wire test clause 13.3.2 | 2021-05-19 | |
LITE | IEC 60598-2-1:2020 | Accepted clauses:Adjusting devices test: clause 1.6Impact test: clause 1.6Mechanical suspensions fixing and connections: clause 1.6Earth continuity test clause 1.8Resistance to moisture: clause 1.13Insulation resistance: clause 1.14Electric strength clause 1.14Thermal test clause 1.12Glow wire test clause 1.15 | 2021-05-19 | |
LITE | IEC 60598-2-2:2011 | Accepted clauses:Adjusting devices test: clause 2.7Impact test: clause 2.7Mechanical suspensions,fixing and connections: clause 2.7Earth continuity test clause 2.9Resistance to moisture: clause 2.14Insulation resistance: clause 2.15Electric strength clause 2.15Thermal test clause 2.13Glow wire test clause 2.16 | 2020-03-06 | |
LITE | IEC 60598-2-4:2017 | Accepted clauses:Adjusting devices test: clause 4.6Impact test: clause 4.6Overturn test clause 4.6.3Earth continuity test clause 4.8Resistance to moisture: clause 4.13Insulation resistance: clause 4.14Electric strength clause 4.14Thermal test clause 4.12Glow wire test clause 4.15 | 2020-03-06 | |
LITE | IEC 60598-2-5:2015 | Accepted clauses:Impact test: clause 5.6Adjusting devices test: clause 5.6Glass impact test: clause 5.6.8.1Earth continuity test clause 5.8Resistance to moisture: clause 5.13Insulation resistance: clause 5.14Electric strength clause 5.14Thermal test clause 5.12Glow wire test clause 5.15 | 2020-03-06 |