MinebeaMitsumi Technology Center Europe GmbH
MinebeaMitsumi Technology Center Europe GmbH
Address(es) |
|
Website | Not available |
Status | WITHDRAWN |
Acceptance date | 2021-03-08 |
Further information
Stage | Country | Name |
---|---|---|
2 | Norway |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
HOUS | IEC 60335-1:2010 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2 | 2021-03-08 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2 | 2021-03-08 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2 | 2021-03-08 | |
HOUS | IEC 60335-2-6:2014 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2 | 2021-03-08 | |
HOUS | IEC 60335-2-6:2014/AMD1:2018 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2 | 2021-03-08 | |
HOUS | IEC 60335-2-24:2010 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2, Annex AA | 2021-03-08 | |
HOUS | IEC 60335-2-24:2010/AMD1:2012 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2, Annex AA | 2021-03-08 | |
HOUS | IEC 60335-2-24:2010/AMD2:2017 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2, Annex AA | 2021-03-08 | |
HOUS | IEC 60335-2-40:2013 | Accepted clauses:10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2 | 2021-03-08 | |
HOUS | IEC 60335-2-40:2013/AMD1:2016 | Accepted clauses:10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2 | 2021-03-08 | |
HOUS | IEC 60335-2-80:2015 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2 | 2021-03-08 | |
HOUS | IEC 60335-2-89:2010 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2, Annex AA | 2021-03-08 | |
HOUS | IEC 60335-2-89:2010/AMD1:2012 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2, Annex AA | 2021-03-08 | |
HOUS | IEC 60335-2-89:2010/AMD2:2015 | Accepted clauses: 10.1, 11.8, 13.2, 13.3, 15.3, 16.2, 16.3, 19.7, 19.11.1, 19.11.2, 19.11.3, 29.1, 29.2, Annex AA | 2021-03-08 | |
ITAV | IEC 62368-1:2018 | Accepted clauses: 5.2.2.2, 5.4.1.4, 5.4.2, 5.4.3, 5.4.4, 5.4.8, 5.4.9, 5.7, 6.2.2.2,6.2.2.3, 6.2.3.2, 9.2.5, B.2.5, B.3, B.4, F, G.5.4.5, G.5.4.6,G.5.4.7, T.3 | 2021-03-08 | |
ITAV | IEC 62368-1:2014 | Accepted clauses: 5.2.2.2, 5.4.1.4, 5.4.2, 5.4.3, 5.4.4, 5.4.8, 5.4.9, 5.7, 6.2.2.2, 6.2.2.3, 6.2.3.2, 9.2.5, B.2.5, B.3, B.4, F, G.5.4.5, G.5.4.6, G.5.4.7, T.3 | 2021-03-08 | |
OFF | IEC 60950-1:2005 | Accepted clauses: 1.6.2, 1.7.11, 2.9.2, 2.10.3, 2.10.4, 2.10.5, 4.2.3, 4.4, 4.5, 5.1.5, 5.2, 5.3, Annex B, Annex F | 2021-03-08 | |
OFF | IEC 60950-1:2005/AMD1:2009 | Accepted clauses: 1.6.2, 1.7.11, 2.9.2, 2.10.3, 2.10.4, 2.10.5, 4.2.3, 4.4, 4.5, 5.1.5, 5.2, 5.3, Annex B, Annex F | 2021-03-08 | |
OFF | IEC 60950-1:2005/AMD2:2013 | Accepted clauses: 1.6.2, 1.7.11, 2.9.2, 2.10.3, 2.10.4, 2.10.5, 4.2.3, 4.4, 4.5, 5.1.5, 5.2, 5.3, Annex B, Annex F | 2021-03-08 |