GD Midea Air-conditioning Equipment Co., Ltd.
GD Midea Air-conditioning Equipment Co., Ltd.
Address(es) |
|
Website | https://www.midea.com.cn |
Status | MEMBER |
Acceptance date | 2015-11-10 |
Further information
Stage | Country | Name |
---|---|---|
1 | Finland |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
HOUS | IEC 60335-1:2020 | Accepted clauses 7-10, 11, 13, 15, 16, 17, 19-30 (Excluding 8.1.4, 19.11.4,22.46) | 2022-03-10 | |
HOUS | IEC 60335-1:2010 | Accepted clauses 7-10, 11, 13, 15, 16, 17, 19-30 (Excluding 8.1.4, 19.11.4, 22.46) | 2021-03-15 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | Accepted clauses 7-10, 11, 13, 15, 16, 17, 19-30 (Excluding 8.1.4, 19.11.4, 22.46) | 2021-03-15 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | Accepted clauses 7-10, 11, 13, 15, 16, 17, 19-30 (Excluding 8.1.4, 19.11.4, 22.46) | 2021-03-15 | |
HOUS | IEC 60335-1:2001 | Accepted clauses 7-10, 11, 13, 15, 16, 17, 19-30 (Excluding 8.1.4, 19.11.4, 22.46) | 2021-03-15 | |
HOUS | IEC 60335-1:2001/AMD1:2004 | Accepted clauses 7-10, 11, 13, 15, 16, 17, 19-30 (Excluding 8.1.4, 19.11.4, 22.46) | 2021-03-15 | |
HOUS | IEC 60335-1:2001/AMD2:2006 | Accepted clauses 7-10, 11, 13, 15, 16, 17, 19-30 (Excluding 8.1.4, 19.11.4, 22.46) | 2021-03-15 | |
HOUS | IEC 60335-2-40:2022 | Accepted clauses 7-10, 11, 13, 15, 16, 17, 19-30 (Excluding 8.1.4, 19.11.4,22.46) | 2023-11-08 | |
HOUS | IEC 60335-2-40:2018 | Accepted clauses 7-10,11,13,15,16,17,19-30 (Excluding 8.1.4, 19.11.4,22.46, 32.101, Annex K, Annex OO) | 2019-11-29 | |
HOUS | IEC 60335-2-40:2013 | Accepted clauses 7-10,11,13,15,16,17,19-30 (Excluding 8.1.4, 19.11.4,22.46) | 2015-11-10 | |
HOUS | IEC 60335-2-40:2013/AMD1:2016 | Accepted clauses 7-10,11,13,15,16,17,19-30 (Excluding 8.1.4, 19.11.4,22.46) | 2016-06-10 | |
HOUS | IEC 60335-2-40:2002 | Accepted clauses 7-10,11,13,15,16,17,19-30 (Excluding 8.1.4, 19.11.4,22.46) | 2015-11-10 | |
HOUS | IEC 60335-2-40:2002/AMD1:2005 | Accepted clauses 7-10,11,13,15,16,17,19-30 (Excluding 8.1.4, 19.11.4,22.46) | 2015-11-10 | |
HOUS | IEC 60335-2-40:2002/AMD2:2005 | since 2016-06-16: Accepted clauses 7-10,11,13,15,16,17,19-30 (Excluding 8.1.4, 19.11.4,22.46)until 2016-06-15: Accepted clauses:clauses 7-10, 11, 13, 15, 16, 17, 19-30 | 2015-11-10 |