Central Laboratory of Gree Electric Appliance Inc. of Zhuhai
Central Laboratory of Gree Electric Appliance Inc. of Zhuhai
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2012-12-14 |
Further information
Stage | Country | Name |
---|---|---|
1 | Finland |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
EMC | CISPR 14-1:2020 | All Clauses | 2022-06-29 | |
EMC | CISPR 14-1:2016 | All clauses. | 2019-10-08 | |
EMC | CISPR 14-1:2005 | All clauses. | 2015-06-21 | |
EMC | CISPR 14-1:2005/AMD1:2008 | All clauses. | 2015-06-21 | |
EMC | CISPR 14-1:2005/AMD2:2011 | All clauses. | 2015-06-21 | |
EMC | CISPR 14-2:2020 | All Clauses | 2022-06-29 | |
EMC | CISPR 14-2:2015 | All clauses. | 2017-07-26 | |
EMC | CISPR 14-2:1997 | Since 2016-09-22: all clauses.Since 2015-06-21: Accepted clauses: All the clauses except the clause 5.5: Radiated Immunity test item. | 2015-06-21 | |
EMC | CISPR 14-2:1997/AMD1:2001 | Since 2016-09-22: all clauses.Since 2015-06-21: Accepted clauses: All the clauses except the clause 5.5: Radiated Immunity test item. | 2015-06-21 | |
EMC | CISPR 14-2:1997/AMD2:2008 | Since 2016-09-22: all clauses.Since 2015-06-21: Accepted clauses: All the clauses except the clause 5.5: Radiated Immunity test item. | 2015-06-21 | |
EMC | IEC 61000-3-2:2018 | All clauses. | 2019-10-08 | |
EMC | IEC 61000-3-2:2018/AMD1:2020 | All Clauses | 2022-06-29 | |
EMC | IEC 61000-3-2:2014 | All clauses. | 2017-07-26 | |
EMC | IEC 61000-3-2:2005 | all clauses | 2015-06-21 | |
EMC | IEC 61000-3-2:2005/AMD1:2008 | all clauses | 2015-06-21 | |
EMC | IEC 61000-3-2:2005/AMD2:2009 | all clauses | 2015-06-21 | |
EMC | IEC 61000-3-3:2013 | All clauses. | 2017-07-26 | |
EMC | IEC 61000-3-3:2013/AMD1:2017 | All clauses. | 2019-10-08 | |
EMC | IEC 61000-3-3:2013/AMD2:2021 | All Clauses | 2022-06-29 | |
EMC | IEC 61000-3-3:2008 | all clauses | 2015-06-21 | |
EMC | IEC 61000-4-13:2002 | All clauses. | 2020-11-25 | |
EMC | IEC 61000-4-13:2002/AMD1:2009 | All clauses. | 2020-11-25 | |
EMC | IEC 61000-4-13:2002/AMD2:2015 | All clauses. | 2020-11-25 | |
HOUS | IEC 60335-1:2020 | Clauses 7, 8, 10, 11, 13, 15 (only IPX3 and IPX4), 16, 17, 19, 20, 21 and 23 to 30. | 2022-06-29 | |
HOUS | IEC 60335-1:2010 | clauses 7, 8, 10, 11, 13, 15 (only IPX3 and IPX4), 16, 17, 19, 20, 21 and 23 to 30. | 2010-12-21 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | clauses 7, 8, 10, 11, 13, 15 (only IPX3 and IPX4), 16, 17, 19, 20, 21 and 23 to 30. | 2015-06-20 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | clauses 7, 8, 10, 11, 13, 15 (only IPX3 and IPX4), 16, 17, 19, 20, 21 and 23 to 30. | 2017-07-26 | |
HOUS | IEC 60335-1:2001 | clauses 7, 8, 10, 11, 13, 15 (only IPX3 and IPX4), 16, 17, 19, 20, 21 and 23 to 30. | 2012-12-14 | |
HOUS | IEC 60335-1:2001/AMD1:2004 | clauses 7, 8, 10, 11, 13, 15 (only IPX3 and IPX4), 16, 17, 19, 20, 21 and 23 to 30. | 2012-12-14 | |
HOUS | IEC 60335-1:2001/AMD2:2006 | clauses 7, 8, 10, 11, 13, 15 (only IPX3 and IPX4), 16, 17, 19, 20, 21 and 23 to 30. | 2012-12-14 | |
HOUS | IEC 60335-2-40:2022 | 10, 11, 13, 16, 19, 20, 21 and 23 to 30. | 2023-09-01 | |
HOUS | IEC 60335-2-40:2018 | 10, 11, 13, 16, 19, 20, 21 and 23 to 30. | 2019-01-11 | |
HOUS | IEC 60335-2-40:2013 | 10, 11, 13, 16, 19, 20, 21 and 23 to 30. | 2015-06-20 | |
HOUS | IEC 60335-2-40:2013/AMD1:2016 | 10, 11, 13, 16, 19, 20, 21 and 23 to 30. | 2017-07-26 | |
HOUS | IEC 60335-2-40:2002 | 10, 11, 13, 16, 19, 20, 21 and 23 to 30. | 2010-12-21 | |
HOUS | IEC 60335-2-40:2002/AMD1:2005 | 10, 11, 13, 16, 19, 20, 21 and 23 to 30. | 2010-12-21 | |
HOUS | IEC 60335-2-40:2002/AMD2:2005 | 10, 11, 13, 16, 19, 20, 21 and 23 to 30. | 2010-12-21 |