BLOCK Transformatoren-Elektronik GmbH

Address(es)
  • Max-Planck-Straße 36-46,
    DE-27283 Verden
    Germany

Website Not available
Status

MEMBER

Acceptance date 2022-07-06

Further information

Stage

Country

Name

2

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

MEAS

SINGLE FAULT CONDITION TESTS (4.4)COMPONENT ABNORMAL (4.4.1)MAINS TRANSFORMER SHORT CIRCUIT TEST (4.4.2.7.2)MAINS TRANSFORMER OVERLOAD TEST (4.4.2.7.3)OUTPUT ABNORMAL TEST (4.4.2.8)MAINS SUPPLY (5.1.3)DURABILITY OF MARKING TEST (5.3)DETERMINATION OF ACCESSIBLE PARTS (6.2)LIMIT VALUES FOR ACCESSIBLE PARTS (6.3)GROUNDING CONTINUITY TEST (6.5.2.4 AND 6.5.2.5)LIMITED SHORT-CIRCUIT TEST (6.5.2.4DV)INSULATION REQUIREMENTS (6.7, ANNEX K)DIELECTRIC VOLTAGE WITHSTAND TEST (6.8)HUMIDITY CONDITIONING TEST (6.8.2)SHARP EDGES (7.2)LIMITATION OF FORCE AND PRESSURE (7.3.4)GAP LIMITATION BETWEEN MOVING PARTS ACCESS NORMALLY PREVENTED (7.3.5.2)WALL MOUNTING TEST (7.6)RIGIDITY TEST (8.2.1)IMPACT TEST (8.2.2)DROP TEST OTHER THAN HAND HELD EQUIPMENT AND DIRECT PLUG IN EQUIPMENT (8.3.1)TEMPERATURE TEST (10.1-10.4)(61010-2-201,2ND ED. 10.4.1.100–10.4.1.103)INTEGRITY OF CLEARANCES AND CREEPAGES TEST (10.5.1)BALL PRESSURE TEST (10.5.3)
2022-07-06

MEAS

SINGLE FAULT CONDITION TESTS (4.4)COMPONENT ABNORMAL (4.4.1)MAINS TRANSFORMER SHORT CIRCUIT TEST (4.4.2.7.2)MAINS TRANSFORMER OVERLOAD TEST (4.4.2.7.3)OUTPUT ABNORMAL TEST (4.4.2.8)MAINS SUPPLY (5.1.3)DURABILITY OF MARKING TEST (5.3)DETERMINATION OF ACCESSIBLE PARTS (6.2)LIMIT VALUES FOR ACCESSIBLE PARTS (6.3)GROUNDING CONTINUITY TEST (6.5.2.4 AND 6.5.2.5)LIMITED SHORT-CIRCUIT TEST (6.5.2.4DV)INSULATION REQUIREMENTS (6.7, ANNEX K)DIELECTRIC VOLTAGE WITHSTAND TEST (6.8)HUMIDITY CONDITIONING TEST (6.8.2)SHARP EDGES (7.2)LIMITATION OF FORCE AND PRESSURE (7.3.4)GAP LIMITATION BETWEEN MOVING PARTS ACCESS NORMALLY PREVENTED (7.3.5.2)WALL MOUNTING TEST (7.6)RIGIDITY TEST (8.2.1)IMPACT TEST (8.2.2)DROP TEST OTHER THAN HAND HELD EQUIPMENT AND DIRECT PLUG IN EQUIPMENT (8.3.1)TEMPERATURE TEST (10.1-10.4)(61010-2-201,2ND ED. 10.4.1.100–10.4.1.103)INTEGRITY OF CLEARANCES AND CREEPAGES TEST (10.5.1)BALL PRESSURE TEST (10.5.3)
2022-07-06

MEAS

TEMPERATURE TEST (10.4.1.100–10.4.1.103)OVERLOAD AND ENDURANCE TEST - GENERAL USE AND RESISTIVE LOADS (UL/CSA/IEC 61010-2-201, 4.4.1.101.1, 4.4.1.101.2):OVERLOAD AND ENDURANCE TEST - PILOT DUTY LOADS (UL/CSA/IEC 61010-2-201, 4.4.1.101.1, 4.4.1.101.2)
2023-07-05