CTF

Acbel Electronic (Dong Guan) Co., Ltd

 
  •  

Standards in Scope

Category
Standard
Tests/Clauses
Acceptance Date
Responsible National Certification Body(s)
OFFIEC 60950-1:2005
Accepted clauses 1.6.2 Input current test 1.7.11 Durability test 2.1.1.5 Max output measurement 2.1.1.7 Energy discharge test 2.2 SELV circuits test 2.4 Limited current circuits test 2.5 Limited power source test 2.6.3.4 Grounding continuity test 2.9.2 Humidity conditioning test 2.10 Clearances, creepage distances and distances through insulation test 3.2.6 Cord anchorages and strain relief test 4.2.2 Steady force test, 10 N 4.2.3 Steady force test, 30 N 4.2.4 Steady force test, 250 N 4.2.5 Impact test 4.2.6 Drop test 4.2.7 Stress relief test 4.5 Thermal requirements 4.5.5 Resistance to abnormal heat 5.1 Touch current and protective conductor current 5.2 Electric strength test 5.3 Abnormal operating and fault conditions
2018-01-31
OFFIEC 60950-1:2005/AMD1:2009
Accepted clauses 1.6.2 Input current test 1.7.11 Durability test 2.1.1.5 Max output measurement 2.1.1.7 Energy discharge test 2.2 SELV circuits test 2.4 Limited current circuits test 2.5 Limited power source test 2.6.3.4 Grounding continuity test 2.9.2 Humidity conditioning test 2.10 Clearances, creepage distances and distances through insulation test 3.2.6 Cord anchorages and strain relief test 4.2.2 Steady force test, 10 N 4.2.3 Steady force test, 30 N 4.2.4 Steady force test, 250 N 4.2.5 Impact test 4.2.6 Drop test 4.2.7 Stress relief test 4.5 Thermal requirements 4.5.5 Resistance to abnormal heat 5.1 Touch current and protective conductor current 5.2 Electric strength test 5.3 Abnormal operating and fault conditions
2018-01-31
OFFIEC 60950-1:2005/AMD2:2013
Accepted clauses 1.6.2 Input current test 1.7.11 Durability test 2.1.1.5 Max output measurement 2.1.1.7 Energy discharge test 2.2 SELV circuits test 2.4 Limited current circuits test 2.5 Limited power source test 2.6.3.4 Grounding continuity test 2.9.2 Humidity conditioning test 2.10 Clearances, creepage distances and distances through insulation test 3.2.6 Cord anchorages and strain relief test 4.2.2 Steady force test, 10 N 4.2.3 Steady force test, 30 N 4.2.4 Steady force test, 250 N 4.2.5 Impact test 4.2.6 Drop test 4.2.7 Stress relief test 4.5 Thermal requirements 4.5.5 Resistance to abnormal heat 5.1 Touch current and protective conductor current 5.2 Electric strength test 5.3 Abnormal operating and fault conditions
2018-01-31
TRONIEC 60065:2014
Accepted clauses 5.1 Durability test 7.1 Heating under normal operating conditions 9.1.1.2 Determination of hazardous live parts 9.1.6 Withdrawal of mains plug 9.1.7 Resistance to external forces 10.3 Humidity treatment 10.4 Insulation resistance and dielectric strength 11 Fault conditions 12.1.4 Impact test 12.1.5 Drop test 12.1.6 Stress relief test 13.2 Determination of working voltage 13.3 Clearances 13.4 Creepage distances 15.2 Provisions for protective earthing 15.4.3 The device shall have adequate mechanical strength. 16.5 Strain relief test for external flexible cords
2018-01-31
IEC 62368-1:2014
Accepted clauses 4.4.2, Annex T.2, T.3, T.4, T.5 Steady force tests 4.4.4.3, Annex T.7 Drop tests 4.4.4.4, Annex T.6 Impact tests 4.4.4.7, Annex T.8 Stress relief test 5.2 Classification and limits of electrical energy sources 5.4.1,10.3 Ball pressure test 5.4.1.4 Maximum operating temperatures for materials, components and systems 5.4.1.8 Determination of working voltage 5.4.8 Humidity conditioning 5.4.9, 5.4.4.6.2 Electric strength test and Separable thin sheet material 5.5.2.2 Safeguards against capacitor discharge after disconnection of connector 5.6.6 Resistance of the protective bonding system 5.7 Prospective touch voltage, touch current and protective conductor current 5.7.5 Protective conductor current 6.2.2 Power source circuit classifications 6.2.3.1 Arcing PIS 6.2.3.2 Resistive PIS Annex B.3 Simulated abnormal operating conditions Annex B.4 Simulated single fault conditions Annex Q.1 Limited power source Annex B.2.5 Input test Annex G.7.3.2 Cord strain relief
2018-01-31