CTF

Delta Electronics, Inc.

 
  •  

Standards in Scope

Category
Standard
Tests/Clauses
Acceptance Date
Responsible National Certification Body(s)
ITAVIEC 62368-1:2018
4.4.3.2, ANNEX T.4 - STEADY FORCE TEST, 100 N 4.4.3.2, ANNEX T.5 - STEADY FORCE TEST, 250 N 4.4.3.2, ANNEX T.3 - STEADY FORCE TEST, 30 N 4.4.3.3, ANNEX T.7 - DROP TEST 4.4.3.4, ANNEX T.6 - IMPACT TEST 4.4.3.8, ANNEX T.8 - STRESS RELIEF TEST 5.4.1.4, Annex B.2 - MAXIMUM OPERATING TEMPERATURE FOR MATERIALS, COMPONENTS AND SYSTEMS 6.2.2.2, 6.2.2.3 - POWER MEASUREMENTS 6.3 - NORMAL OPERATING CONDITIONS TEMPERATURE TEST 6.4.3, ANNEX B.4 - REDUCTION OF THE LIKELIHOOD OF IGNITION UNDER SINGLE FAULT CONDITIONS 6.4.3.3 - REDUCTION OF THE LIKELIHOOD OF IGNITION - TEMPERATURES LIMITED BY FUSES 6.6 - TEST TO DETERMINE DELIVERED POWER: PS2 DETERMINATION 8.6.2 - STATIC STABILITY B.2.5 - INPUT TEST: SINGLE PHASE B.2.6 - NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENT B.3 - SIMULATED ABNORMAL OPERATING CONDITIONS B.4 - SIMULATED SINGLE FAULT CONDITIONS 6.4.2, ANNEX B.4 - SINGLE FAULT CONDITIONS: REDUCE THE LIKELIHOOD OF IGNITION ANNEX F.3.10 – TEST FOR THE PERMANENCE OF MARKINGS G.5.4.6 - LOCKED-ROTOR OVERLOAD TEST FOR D.C. MOTORS G.5.4.6.3 - ALTERNATIVE LOCKED-ROTOR OVERLOAD TEST FOR D.C. MOTORS ANNEX M.3.2 – PROTECTION CIRCUITS FOR BATTERIES ANNEX Q.1 - LIMITED POWER SOURCE ANNEX T.2 , 5.4.2.6, 5.4.3.2, G.15.3.6 – STEADY FORCE TEST, 10 N
2020-05-28
ITAVIEC 62368-1:2014
4.4.4.2, ANNEX T.4 - STEADY FORCE TEST, 100 N 4.4.4.2, ANNEX T.5 - STEADY FORCE TEST, 250 N 4.4.4.3, ANNEX T.7 - DROP TEST 4.4.4.4, ANNEX T.6 - IMPACT TEST 4.4.4.7, ANNEX T.8 - STRESS RELIEF TEST 6.2.2.2, 6.2.2.3 - POWER MEASUREMENTS 6.3 - NORMAL OPERATING CONDITIONS TEMPERATURE TEST 6.4.3, ANNEX B.4 - REDUCTION OF THE LIKELIHOOD OF IGNITION UNDER SINGLE FAULT CONDITIONS 6.4.3.3 - REDUCTION OF THE LIKELIHOOD OF IGNITION - TEMPERATURES LIMITED BY FUSES 6.6 - TEST TO DETERMINE DELIVERED POWER: PS2 DETERMINATION 8.6.2 - STATIC STABILITY B.2.5 - INPUT TEST: SINGLE PHASE B.2.6 - NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENT B.3 - SIMULATED ABNORMAL OPERATING CONDITIONS B.4 - SIMULATED SINGLE FAULT CONDITIONS 6.4.2, ANNEX B.4 - SINGLE FAULT CONDITIONS: REDUCE THE LIKELIHOOD OF IGNITION ANNEX F.3.10 – TEST FOR THE PERMANENCE OF MARKINGS G.5.4.6 - LOCKED-ROTOR OVERLOAD TEST FOR D.C. MOTORS G.5.4.6.3 - ALTERNATIVE LOCKED-ROTOR OVERLOAD TEST FOR D.C. MOTORS ANNEX M.3.2 – PROTECTION CIRCUITS FOR BATTERIES ANNEX Q.1 - LIMITED POWER SOURCE ANNEX T.2 , 5.4.2.6, 5.4.3.2, G.15.3.6 – STEADY FORCE TEST, 10 N
2019-01-04
OFFIEC 60950-1:2005
1.6.2 - INPUT TEST: SINGLE - PHASE 1.7.11 - DURABILITY OF MARKING TEST 2.1.1.5, 2.1.2, 1.2.8.10 - ENERGY HAZARD MEASUREMENTS 2.2.2, 2.2.3, 2.2.4, PART 22 6.1 - SELV RELIABILITY TEST 2.5 - LIMITED POWER SOURCE MEASUREMENTS 4.1 - STABILITY TESTS 4.2.1-4.2.4 - STEADY FORCE TESTS 4.2.5, 4.2.1, PART 22.10.2 - IMPACT TEST 4.2.6, 4.2.1 - DROP TEST 4.2.7, 4.2.1 - Stress Relief Test 4.2.10 - LOADING TESTS – WALL AND CEILING MOUNTED EQUIPMENT 4.3.8 - BATTERY TESTS 4.3.8 - LITHIUM BATTERY REVERSE CURRENT MEASUREMENT TEST 4.4.2, .4.4 - HAZARDOUS MOVING PARTS TEST 4.5.1, 1.4.12, 1.4.13 - HEATING TEST 5.3.1, 5.3.4, 5.3.7 - COMPONENT FAILURE TEST 5.3.1 - ABNORMAL OPERATON TESTS 5.3.7 - OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST 6.2.2 (6.2.2.1) - Electric Strength Test Procedure - Impulse Test 6.2.2 (6.2.2.2) - Electric Strength Test Procedure ‐ Steady‐State Test ANNEX B.7 - LOCKED –ROTOR OVERLOAD TEST FOR DC MOTORS IN SECONDARY
2019-01-04
OFFIEC 60950-1:2005/AMD1:2009
1.6.2 - INPUT TEST: SINGLE - PHASE 1.7.11 - DURABILITY OF MARKING TEST 2.1.1.5, 2.1.2, 1.2.8.10 - ENERGY HAZARD MEASUREMENTS 2.2.2, 2.2.3, 2.2.4, PART 22 6.1 - SELV RELIABILITY TEST 2.5 - LIMITED POWER SOURCE MEASUREMENTS 4.1 - STABILITY TESTS 4.2.1-4.2.4 - STEADY FORCE TESTS 4.2.5, 4.2.1, PART 22.10.2 - IMPACT TEST 4.2.6, 4.2.1 - DROP TEST 4.2.7, 4.2.1 - Stress Relief Test 4.2.10 - LOADING TESTS – WALL AND CEILING MOUNTED EQUIPMENT 4.3.8 - BATTERY TESTS 4.3.8 - LITHIUM BATTERY REVERSE CURRENT MEASUREMENT TEST 4.4.2, .4.4 - HAZARDOUS MOVING PARTS TEST 4.5.1, 1.4.12, 1.4.13 - HEATING TEST 5.3.1, 5.3.4, 5.3.7 - COMPONENT FAILURE TEST 5.3.1 - ABNORMAL OPERATON TESTS 5.3.7 - OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST 6.2.2 (6.2.2.1) - Electric Strength Test Procedure - Impulse Test 6.2.2 (6.2.2.2) - Electric Strength Test Procedure ‐ Steady‐State Test ANNEX B.7 - LOCKED –ROTOR OVERLOAD TEST FOR DC MOTORS IN SECONDARY
2019-01-04
OFFIEC 60950-1:2005/AMD2:2013
1.6.2 - INPUT TEST: SINGLE - PHASE 1.7.11 - DURABILITY OF MARKING TEST 2.1.1.5, 2.1.2, 1.2.8.10 - ENERGY HAZARD MEASUREMENTS 2.2.2, 2.2.3, 2.2.4, PART 22 6.1 - SELV RELIABILITY TEST 2.5 - LIMITED POWER SOURCE MEASUREMENTS 4.1 - STABILITY TESTS 4.2.1-4.2.4 - STEADY FORCE TESTS 4.2.5, 4.2.1, PART 22.10.2 - IMPACT TEST 4.2.6, 4.2.1 - DROP TEST 4.2.7, 4.2.1 - Stress Relief Test 4.2.10 - LOADING TESTS – WALL AND CEILING MOUNTED EQUIPMENT 4.3.8 - BATTERY TESTS 4.3.8 - LITHIUM BATTERY REVERSE CURRENT MEASUREMENT TEST 4.4.2, .4.4 - HAZARDOUS MOVING PARTS TEST 4.5.1, 1.4.12, 1.4.13 - HEATING TEST 5.3.1, 5.3.4, 5.3.7 - COMPONENT FAILURE TEST 5.3.1 - ABNORMAL OPERATON TESTS 5.3.7 - OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST 6.2.2 (6.2.2.1) - Electric Strength Test Procedure - Impulse Test 6.2.2 (6.2.2.2) - Electric Strength Test Procedure ‐ Steady‐State Test ANNEX B.7 - LOCKED –ROTOR OVERLOAD TEST FOR DC MOTORS IN SECONDARY
2019-01-04