CONTIEC 60730-1:2013
10.2.4.3 PUSH/PULL TEST FOR TABS 12.2 PROTECTION AGAINST HUMID CONDITIONS 13.2 ELECTRIC STRENGTH TEST 14 HEATING TEST 16 ENVIRONMENTAL STRESS OF TEMPERATURE 17 ENDURANCE TEST (EXCEPT MANUAL ACTION) 20.3 CREAPAGE AND CLEARANCE - SOLID INSULATION 22.1 RESISTANCE TO CORROSION 27.3 OVERVOLTAGE AND UNDERVOLTAGE 9.3 ADEQUACY OF EARTH CONNECTIONS TEST ANNEX A INDELIBILITY OF MARKINGS TEST H.11.4, H.27.4 ELECTRONIC DISCONNECT TEST H.17.1.4.2 THERMAL CYCLING TEST H.26.10 RING WAVE IMMUNITY H.26.11 ELECTROSTATIC DISCHARGE TEST H.26.12.2 RADIO-FREQUENCY ELECTROMAGNETIC FIELD IMMUNITY - IMMUNITY TO CONDUCTED DISTURBANCES H.26.12.3 RADIATED ELECTROMAGNETIC FIELDS IMMUNITY EVALUATION H.26.13 TEST OF INFLUENCE OF SUPPLY FREQUENCY VARATIONS H.26.14 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST H.26.15 EVALUATION OF COMPLIANCE H.26.5 VOLTAGE DIPS, VOLTAGE INTERRUPTIONS AND VOLTAGE VARIATIONS IN THE POWER SUPPLY NETWORK H.26.5.4 VOLTAGE DIPS AND VOLTAGE INTERRUPTIONS IN THE POWER SUPPLY NETWORK - VOLTAGE VARIATION H.26.8 SURGE IMMUNITY H.26.9 ELECTRICAL FAST TRANSIENT/ BURST IMMUNITY H.27.1.1 ABNORMAL OPERATION H.27.1.4 ELECTRONIC CIRCUIT FAULTS
2019-08-13
CONTIEC 60730-1:2010
10.2.4.3 PUSH/PULL TEST FOR TABS 12.2 PROTECTION AGAINST HUMID CONDITIONS 13.2 ELECTRIC STRENGTH TEST 14 HEATING TEST 16 ENVIRONMENTAL STRESS OF TEMPERATURE 17 ENDURANCE TEST(EXCEPT MANUAL ACTION) 20.3 CREAPAGE AND CLEARANCE - SOLID INSULATION 22.1 RESISTANCE TO CORROSION 27.3 OVERVOLTAGE AND UNDERVOLTAGE 9.3 ADEQUACY OF EARTH CONNECTIONS TEST ANNEX A INDELIBILITY OF MARKINGS TEST H.11.4, H27.4 ELECTRONIC DISCONNECT TEST H.17.1.4.2 THERMAL CYCLING TEST H.26.10 RING WAVE IMMUNITY H.26.11 ELECTROSTATIC DISCHARGE TEST H.26.12.2 RADIO-FREQUENCY ELECTROMAGNETIC FIELD IMMUNITY - IMMUNITY TO CONDUCTED DISTURBANCES H.26.12.3 RADIATED ELECTROMAGNETIC FIELDS IMMUNITY EVALUATION H.26.13 TEST OF INFLUENCE OF SUPPLY FREQUENCY VARIATIONS H.26.14 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST H.26.15 EVALUATION OF COMPLIANCE H.26.5 VOLTAGE DIPS AND VOLTAGE INTERRUPTIONS IN THE POWER SUPPLY NETWORK H.26.5.4 VOLTAGE DIPS AND VOLTAGE INTERRUPTIONS IN THE POWER SUPPLY NETWORK - VOLTAGE VARIATION H.26.8 SURGE IMMUNITY H.26.9 FAST TRANSIENT BURST. H.27.1.1 ABNORMAL OPERATION - ELECTRONIC CONTROLS H.27.1.4 ELECTRONIC CIRCUIT FAULTS
2017-01-02