CTF

Astec International Ltd

 
  •  

Standards in Scope

Category
Standard
Tests/Clauses
Acceptance Date
Responsible National Certification Body(s)
ITAVIEC 62368-1:2014
5.2, 5.7, CLASSIFICATION OF ELECTRICAL ENERGY SOURCES 5.2.1.1, ACCESSIBLE ES1 CIRCUITS SEPARTED FROM OTHER ES CIRCUITS USING COMPONENTS 5.4.1.8, DETERMINATION OF WORKING VOLTAGE 5.4.1.10.3, BALL PRESSURE TEST 5.4.4.6.2, SEPARABLE THIN SHEET MATERIAL 5.4.8, HUMIDITY CONDITIONING 5.4.9, ELECTRIC STRENGTH TEST 5.4.10, SAFEGUARDS AGAINST CAPACITOR DISCHARGE AFTER DISCONNECTION OF A CAPACITOR 5.6.6.5, RESISTANCE OF THE PROTECTIVE BONDING SYSTEM 5.7, PROSPECTIVE TOUCH VOLTAGE AND TOUCH CURRENT MEASUREMENT 5.7.5, PROTECTIVE CONDUCTOR CURRENT 6.6.5.2, 6.2.2.3, POWER MEASUREMENTS Annex B.2.5, INPUT TEST: SINGLE PHASE ANNEX B.2.6, NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENT ANNEX B.3, SIMULATED ABNORMAL OPERATING CONDITIONS ANNEX B.4, SIMULATED SINGLE FAULT CONDITIONS ANNEX F.3.10, TEST FOR THE PERMANENCE OF MARKINGS ANNEX G.5.3.3, TRANSFORMER OVERLOAD ANNEX R.1, 5.6.4.1, 5.6.4.4, 5.6.5.1, LIMITED SHORT CIRCUIT TEST ANNEX T.3 (5.4.2.6, 5.4.3.2, G15.3.6, STEADY FORCE TEST, 10 N ANNEX T.4 (4.4.4.2), STEADY FORCE TEST, 250 N ANNEX T.6 (4.4.4.4, 8.10.4), ENCLOSURE IMPACT TEST
2019-09-18
OFFIEC 60950-1:2005
1.2.2.1 Guide Information Page - Maximum Output Voltage, Current, and Volt Ampere Measurement 1.6.2 Input: Single-Phase 1.6.2 Input: Polyphase 1.7.11 Durability of Marking 2.1.1.1, 2.8.2, Part 21 4.2 Access To Energized Parts Test 2.1.1.5, 2.1.2, 1.2.8.10 Energy Hazard Measurements 2.1.1.7 Capacitance Discharge 2.2.2, 2.2.3, 2.2.4, Part 22 6.1 Selv Reliability Test Including Hazardous Voltage Measurements 2.4.1, 2.4.2 Limited Current Circuit Measurement 2.5 Limited Power Source Measurement 2.6.3.4, 2.6.1 Protective Bonding I 2.6.3.4, 2.6.1 Protective Bonding II 2.9.1, 2.9.2, 5.2.2 Humidity 2.10.2 Determination Of Working Voltage; Working Voltage Measurement 2.10.5.9, 2.10.5.10, 2.10.5.6 Thin Sheet Material Tests 2.10.5.6, 2.10.5.13 Transformer And Wire Insulation Electric Strength Test 3.2.6, 4.2.1, 4.2.7 Strain Relief 4.1 Stability 4.2.1 - 4.2.4 Steady Force 4.2.5, 4.2.1, Part 22 10.2 Impact 4.2.6, 4.2.1 Drop 4.2.7, 4.2.1 Stress Relief 4.3.2 Knob Pull/Handle Loading 4.5.1, 1.4.12, 1.4.13 Heating 4.5.5, 4.5 Ball Pressure 5.1, Annex D Touch Current (Single-Phase; TN/TT System) 5.1, Annex D Touch Current (Polyphase; TN/TT System) 5.1, Annex D IT Touch Current (Single-Phase) 5.2.2 Electric Strength 5.3.1, 5.3.4, 5.3.7 Component Failure 5.3.1 - 5.3.9 Abnormal Operation 5.3.3, 5.3.7b, Annex C.1 Transformer Abnormal Operation 5.3.7 Power Supply Output Short-Circuit/Overload Annex B.7 Locked-Rotor Overload for DC Motors in Secondary Circuits
2019-09-18
OFFIEC 60950-1:2005/AMD1:2009
1.2.2.1 Guide Information Page - Maximum Output Voltage, Current, and Volt Ampere Measurement 1.6.2 Input: Single-Phase 1.6.2 Input: Polyphase 1.7.11 Durability of Marking 2.1.1.1, 2.8.2, Part 21 4.2 Access To Energized Parts Test 2.1.1.5, 2.1.2, 1.2.8.10 Energy Hazard Measurements 2.1.1.7 Capacitance Discharge 2.2.2, 2.2.3, 2.2.4, Part 22 6.1 Selv Reliability Test Including Hazardous Voltage Measurements 2.4.1, 2.4.2 Limited Current Circuit Measurement 2.5 Limited Power Source Measurement 2.6.3.4, 2.6.1 Protective Bonding I 2.6.3.4, 2.6.1 Protective Bonding II 2.9.1, 2.9.2, 5.2.2 Humidity 2.10.2 Determination Of Working Voltage; Working Voltage Measurement 2.10.5.9, 2.10.5.10, 2.10.5.6 Thin Sheet Material Tests 2.10.5.6, 2.10.5.13 Transformer And Wire Insulation Electric Strength Test 3.2.6, 4.2.1, 4.2.7 Strain Relief 4.1 Stability 4.2.1 - 4.2.4 Steady Force 4.2.5, 4.2.1, Part 22 10.2 Impact 4.2.6, 4.2.1 Drop 4.2.7, 4.2.1 Stress Relief 4.3.2 Knob Pull/Handle Loading 4.5.1, 1.4.12, 1.4.13 Heating 4.5.5, 4.5 Ball Pressure 5.1, Annex D Touch Current (Single-Phase; TN/TT System) 5.1, Annex D Touch Current (Polyphase; TN/TT System) 5.1, Annex D IT Touch Current (Single-Phase) 5.2.2 Electric Strength 5.3.1, 5.3.4, 5.3.7 Component Failure 5.3.1 - 5.3.9 Abnormal Operation 5.3.3, 5.3.7b, Annex C.1 Transformer Abnormal Operation 5.3.7 Power Supply Output Short-Circuit/Overload Annex B.7 Locked-Rotor Overload for DC Motors in Secondary Circuits
2019-09-18
OFFIEC 60950-1:2005/AMD2:2013
1.2.2.1 Guide Information Page - Maximum Output Voltage, Current, and Volt Ampere Measurement 1.6.2 Input: Single-Phase 1.6.2 Input: Polyphase 1.7.11 Durability of Marking 2.1.1.1, 2.8.2, Part 21 4.2 Access To Energized Parts Test 2.1.1.5, 2.1.2, 1.2.8.10 Energy Hazard Measurements 2.1.1.7 Capacitance Discharge 2.2.2, 2.2.3, 2.2.4, Part 22 6.1 Selv Reliability Test Including Hazardous Voltage Measurements 2.4.1, 2.4.2 Limited Current Circuit Measurement 2.5 Limited Power Source Measurement 2.6.3.4, 2.6.1 Protective Bonding I 2.6.3.4, 2.6.1 Protective Bonding II 2.9.1, 2.9.2, 5.2.2 Humidity 2.10.2 Determination Of Working Voltage; Working Voltage Measurement 2.10.5.9, 2.10.5.10, 2.10.5.6 Thin Sheet Material Tests 2.10.5.6, 2.10.5.13 Transformer And Wire Insulation Electric Strength Test 3.2.6, 4.2.1, 4.2.7 Strain Relief 4.1 Stability 4.2.1 - 4.2.4 Steady Force 4.2.5, 4.2.1, Part 22 10.2 Impact 4.2.6, 4.2.1 Drop 4.2.7, 4.2.1 Stress Relief 4.3.2 Knob Pull/Handle Loading 4.5.1, 1.4.12, 1.4.13 Heating 4.5.5, 4.5 Ball Pressure 5.1, Annex D Touch Current (Single-Phase; TN/TT System) 5.1, Annex D Touch Current (Polyphase; TN/TT System) 5.1, Annex D IT Touch Current (Single-Phase) 5.2.2 Electric Strength 5.3.1, 5.3.4, 5.3.7 Component Failure 5.3.1 - 5.3.9 Abnormal Operation 5.3.3, 5.3.7b, Annex C.1 Transformer Abnormal Operation 5.3.7 Power Supply Output Short-Circuit/Overload Annex B.7 Locked-Rotor Overload for DC Motors in Secondary Circuits
2019-09-18