| IEC 60598-1(ed.5) | ||||
| Clause | Subject | Keywords | Sheet | |
| General | IEC 62262 |
- IEC 62262 - IK code - Degrees of protection |
003 | |
| General | LEDs used as a ligth source in luminaires |
- LEDs - Harmful radiation - Light intensity |
003/06 | |
| General | LEDs used as a ligth source in luminaires |
- LEDs - Harmful radiation - Light intensity |
DSH 003/06.m | |
| General | IEC 62262/ EN 50102 |
- IEC 62262 - EN 50102 - IK code - Degrees of protection |
002/06 | |
| General 1.7 | Fixed luminaire with track |
- IEC 60570+A1/A2 - 6,5 mm - Track system |
004 | |
| General Section 12 | Luminaires provided with LEDs |
- Control gears - Section 12 - IEC/EN 60825-1 |
DSH 005/06 | |
| General Section 12 | Luminaires provided with LEDs |
- Control gears - Section 12 - IEC/EN 60825-1 |
DSH 005/07 | |
| 0.2 |
- Socket-outlet mounted - Rechargeable luminaire - Rechargeable lamps - Luminaire |
- Socket-outlet mounted - Rechargeable luminaire - Rechargeable lamps - Luminaire |
006 | |
| 0.2 |
- Socket-outlet mounted - Rechargeable luminaire - Rechargeable lamps - Luminaire |
- Socket outlet - Transformer/Plug - Battery chargers |
007/06 | |
| 0.3.1 |
Portable floodlights/lighting chains IP44 |
- Plug - Full - profile - IMQ questionnaire |
007 | |
| 0.4.2 | Range of luminaires |
- Range - N.C.B. - Test Reports |
008 | |
| 0.4.2 | Range of luminaires |
- Working group - Range of luminaires - Experience |
009 | |
| 0.4.2 | Range of luminaires |
- Fluorescent lamps - Same lampholder - Discharge lamps |
009A | |
| 0.4.2 General | Luminaires needing assembly by the user |
- Common sense - Easiness of connection - Pendant luminaires |
011 | |
| 0.4 | Floodlight with mounting accessories |
- Floodlight - Mounting accessories - Part of installation |
012 | |
| 0.4.2 | Instruction manual of a floodlight |
- Mounting instructions - Unfavourable - Instructions manual |
013 | |
| 0.4.2 | Luminaires needing reconnection by the installer |
- Reconnection - Extra terminal - Different voltages or wattages |
260 | |
| 0.5 | Use of 230V components in 240V luminaires |
- UK - 230 V, 240 V - Rated voltage |
014 | |
| 0.5 | Series - compensated luminaire (working voltage) |
- Series capacitors - 450 V - Working voltage |
015 | |
| 0.5 | Connecting device with fuse holder |
- Fuse holder - Connecting device - Fuse |
018 | |
| 0.5 | External cable |
- Cable or cord - Wiring - Luminaires standards |
019 | |
| 0.5 | Luminaire marked for lamp GU 5,3 |
- EPCAP Group - GU 5,3 - GX 5,3 connector |
020 | |
| 0.5 | AC supplied electronic ballasts for discharge lamp luminaires |
- IEC/EN 61347-2-1 - IEC/EN 61347-2-3 - IEC 61347-2-9 §§ 1 -2-7 |
021 | |
| 0.5 |
Completion of Test Report Formats (TRF's) and use of Annex 1 Table of components |
- Components - Certification - TRF |
017/06 | |
| 1.2 | Interconnecting cables |
- 8 cm - 0.75 mm.sq - Internal wiring |
022 | |
| 1.2.24 | Class III luminaire |
- Non-detachable - Transformer - SELV |
023 | |
| 3 | Definition of basic type reference |
- Rated wattage - Type reference - Separately marked |
024 | |
| 3 |
Marking on class III luminaires “system” |
- Connecting device - Each connection - Marking |
261 261 figures |
|
| 3 | Marking of lamp types according to IEC TS 61231 |
- ILCOS codes - IEC TS - Test Reports |
019/06 | |
| 3.2.2 | Rated voltage marking |
- Filament lamps - Rated voltage - Marking |
026 | |
| 3.2.6 | Term "if applicable" |
- IP 20 - Luminaires other than ordinary - If applicable |
027 | |
| 3.2.6 / 9.2 | IP test on recessed luminaires |
- Test recess - Fixed luminaire - Recessed luminaire |
028 | |
| 3.2.6 | Marking with IP numbers |
- IP marking - Mounting orientations - Type designation |
252 | |
| 3.2.8 | Lamp-type information marking |
- Manufacturer - Marking plate - Instructions |
026/06 | |
| 3.2.13 |
Symbol for minimum distance from lighted objects |
- Temperature - Lighted object - Distance symbol |
030 | |
| 3.3 | 3.3 |
- Proper installation - Safety - Markings |
262 | |
|
3.3.7/4.24 Annex P |
UV radiation |
- Protected shield - UV blocked lamp - Mounting height |
031 | |
| 4.2 / 15.7 | Non-detachable flexible cable or cord |
- Component - Conductors - Cable or cord |
032 | |
| 4.2 / 8.2.1 | Luminaire with fuse holder/fuse |
- Entrance - Tool - Marking |
033 | |
| 4.4 | Non standardised lampholder |
- Miscellaneous lampholder - IEC 60838-1 - Built-in / integral |
034 | |
| 4.4.4 | Lampholder fixed by the shade ring |
- Luminare standards - Lampholder - Shade ring |
035 | |
| 4.4.4 ii) | Lampholder mounting brackets |
- Lampholder - Safety - Compliance |
036 | |
| 4.7.2 | Supply terminals (8 mm free wire) |
- Figures 1, 2, 3 - Correct way - Both wires stripped 8 mm |
037 | |
| 4.7.3 | Lampholder terminals |
- Screwless terminal - Rewirable luminaire - Solid/flexible conductors |
DSH 036/06 | |
| 4.7.4 | Terminals for internal and external connections |
- Internal connections - Supply connection - Internal wiring |
039 | |
| 4.8 | Switches for luminaires |
- Switches - 10.000 cycles - IEC 61058-1 |
040 | |
| 4.8 | Electronic switches |
- Electronic switch - LUMEX - IEC 61058-1 |
041 | |
| 4.10 | Insulation required for external and SELV wiring |
- Basic insulation - Double/reinforced insulation - Wiring |
042 | |
| 4.10.1 | Metal suspension device |
- Suspension device - Metal hook - Fixed installation |
043 | |
| 4.10.1 | Sleeves of insulating material |
- Sleeves - Fixed wires - Inside the luminaires |
045 | |
| 4.10.1 | Double and reinforced insulation |
- Enclosure - Mounting surface - Live parts |
046 | |
| 4.11.1 | Contact pressure |
- Construction - Each case - Touch lamp |
047 | |
| 4.11 / 4.12 | Luminaires to be assembled by user |
- User - Earth connection - Ready-made plugs and connectors |
048 | |
| 4.11.3 | Locking device for screws |
- Locking device - Mechanical connections - Fixing screws |
050 | |
| 4.11.3 | Electrical connections |
- Construction - Connections - Locking device |
053 | |
| 4.11.3 / 7 | Crimped connections |
- Relevant tests - Crimped connections - Mechanical/electrical contacts |
054 | |
| 4.11.3 / 7.2.4 | Rivets for electrical and mechanical connections |
- rivets - earthing connections - accidental loosening |
051 | |
| 4.11.3 | Screw connections |
- Small "spikes" - Locking of screw connections - Ballast |
052 | |
| 4.11.4 | Material with equivalent characteristics |
- Material - Equivalent characteristics - Conductive material |
055 | |
| 4.11.5 | Wooden parts on luminaires |
- Wooden parts - Contact with current carrying parts - Supplementary insulation |
056 | |
| 4.12.4 | Portable luminaire; different parts can be loosen by hand |
- Middle pipe - Adequate means - Clause 4.12.4 |
057 | |
| 4.12.4, 4.6 | Mechanical connections, lampholder connections between different parts of luminaires |
- Electrical connections - Strain - Cord anchorage |
523.CTL-ETF5 | |
| 4.13.1 | Mechanical strength |
- Mechanical strength - Light source - Not performed |
058 | |
| 058 | Mechanical strength |
- Three impacts - Weak points - Sample |
059 | |
| 4.14 | Suspension devices |
- Additional weight - Point B and/or C - Design |
060 | |
| 4.14 | Suspension devices for recessed luminaire |
- Fixed luminaires - Fixing devices - Test A |
061 | |
| 4.14.1 | Clip-mounted luminaire |
- Clip-mounted luminaire - Unfavourable condition - Normal use |
062 | |
| 4.14.1 | Clip-mounted luminaire: pulling test |
- Clip-mounted luminaire - No movement - Unfavourable direction |
063 | |
| 063 | Suspended luminaire |
- Flexible cables - Weight - Mass of the luminaire |
064 | |
| 4.14.3 | Screw adjustable by the user |
- Instruction manual - More than 360° - User |
065 | |
| 4.15 / 12.7.1 | Application of clauses 4.15 and 12.7.1 |
- Ballast - Plastic enclosure - Metal "body" |
067 | |
| 4.15 / 12.7.1 | Application of the linear regression formula |
- Both materials - Thermo-resisting bush - Thermoplastic body |
068 | |
| 4.15 a) | Luminaires in thermoplastic material (fixing points) |
- Ballast - Constructive measures - § 4.15 a) / § 12.7.1 |
248 248.figure1 248.figure2 |
|
| 4.15 | Flammable materials |
- Ignition temperature - Life time - Glow wire test |
264 | |
| 4.16 | Temperature sensing control device |
- Reproducibility - Additional fixing - Ballast or transformer |
069 | |
| 4.16.2 / 12.6.2 | Temperature sensing controls |
- Temperature sensing device - PTC or fuse - Transformer and ballast |
070 | |
| 4.21.3 | Luminaires with R7s lamp cap |
- Lamp compartment - Present standard - R7s lamp cap |
071 | |
| 4.21.4 | 4.21.4 |
- Impact test - Outside of the shield - Table 4.3 |
072 | |
| 4.24 | Annex P |
- Lamp manufacturers - Information - Case by case |
073 | |
| 4.24 | Annex P |
- Data - Manufacturer - Procedure A |
074 | |
| 4.24 | Use of different M.H. lamps |
- ILCOS code - Rated current - New lamp |
075 | |
| 4.24 | Protective shield |
- LUMEX - Lamp manufacturers - Technical information |
076 | |
| 4.26 | Test chain |
- Test chain - Tricloroetilene - IEC 60598-1 VI Ed |
077 | |
| 5.2 | Interconnecting cables |
- 8 cm - 0.75 mm.sq - Internal wiring |
022 | |
| 5.2 | Non standardised plug for class III luminaire |
- Sub clause 4.11.6 - Marking - Rated current |
078 | |
| 5.2.2 | Insulation required on a cable (SELV operating) |
- Basic insulated parts - SELV - Cable H03VH-H |
079 | |
| 5.2.2 | External wiring for low voltage luminaire |
- Sub clause 5.2.2 - Standard - External wiring |
080 | |
| 5.2.2 / 5.3.5 | Internal wiring |
- Internal cable - Cord anchorage - Cable length |
081 | |
| 5.2.2 / 7.2.11 | Transparent flexible cords |
- Transparent cable - Earth wire - Green/yellow |
082 | |
| 5.2.8 / 5.3.3 | Push fit bushes |
- Push fit bushes - Properly sized - Standard |
083 | |
| 5.2.10 | Cord anchorage construction |
- Movement - Pushing the cable - Relevant requirements |
084 | |
| 5.2.10 | Flexible cord on recessed luminaire |
- Supply connection - Ordinary luminaires - Flexible cord |
085 | |
| 5.2.10 / 5.3.5 | Cord anchorage on lampholder |
- Class I / II / III - Live parts - Lampholder |
086 | |
| 5.2.10 / 5.3.5 | Cord anchorage on adjustable luminaire |
- Cord anchorage - Adjustable - Cable length |
087 | |
| 5.2.10 / 5.3.5 | Recessed luminaire delivered with separate control gear |
- Complete cord anchorage - Sub clause 5.3.5 - Separate control gear |
088 | |
| 5.2.10.2 / 5.2.10.3 | Cord anchorage with type Y or Z attachment on Printed Circuit Board |
- Cord anchorage - Soldered connection - Type Y or Z attachment |
089 | |
| 5.2.14 / Annex ZB | Portable luminaire |
- UK - IP rated sockets - BS 1363 |
090 | |
| 5.2.16 | Couplers to be used |
- Examples - IEC 60320 - Configurations |
091 | |
| 5.3 | PTFE basic insulated cable |
- 0,6 mm - PVC and rubber - High voltage test |
092 | |
| 5.3 | Internal wiring for some lamp circuits |
- Internal wiring - Insulation resistance - Component |
093 | |
| 5.3.1 | Through wiring in the luminaires |
- Luminaire manufacturer - Skilled persons - Cable/wiring |
094 | |
| 5.3.3 | Use of additional sleeves |
- Construction - Sleeve - Bushings |
095 | |
| 5.3.5 | Interconnecting cables |
- 8 cm - 0.75 mm.sq - Internal wiring |
022 | |
| 7.2 | Locking on earthing connection |
- Construction - During mounting - Spacers |
097 | |
| 7.2.1 | Earthing in luminaire system |
- Metal body - Each luminaire - Fixed installation |
098 | |
| 7.2.1 | Relamping operation |
- Breakage - Insulation fault - Lamp |
099 | |
| 7.2.1 | Provisions for earthing |
- Screws connection - Installation - Cleaning |
100 | |
| 7.2.1 | Electrical connections |
- Mechanical stress - Terminal block - Earth connection |
263 | |
| 7.2.4 | Reliability of the earthing circuit |
- Drawing - Way of earthing - Snap-in pins |
101 | |
| 8 | Standard test finger |
- Cross-section area - External connection - Lampholder terminals |
102 | |
| 8 | Built in components accessibility |
- IP 1X test probe - IEC 60598-1 - Built in components |
103 | |
| 8.2.1 | Luminaires with LEDs |
- Sub clause 8.2.1 - Lamp compartment - Two lines of defence |
251 | |
| 8.2.3 | Class II luminaire with metal reflector |
- Distance - Metal reflector - Lamp replacement |
104 | |
| 8.2.3 | Metal fixing devices for components |
- Live parts - Reinforced insulation - Fixing device |
105 | |
| 8.2.3 | Class I / class II luminaires protection against electric shock |
- D.S. N° 103/03 - Basic insulation - Standard test finger |
266 266.figures |
|
| 8.2.5 | Class II luminaires for discharge lamps |
- Constructions - Common sense - LUMEX |
106 | |
| 8.2.6 | Parts removable by hand |
- Force - Common sense - By hand |
107 | |
| 8.2.7 | Residual voltage |
- One luminaire - System - Requirement |
108 | |
| 9 | IP 65 luminaire |
- All parts - Instructions - Gasket |
109 | |
| 9 | IP 20 luminaire |
- Instruction leaflet - Indoor/outdoor - Glands |
110 | |
| 9 | IP degree |
- IP X3 / X4 - IP X5 / X6 - Procedure |
111 | |
| 9 / 9.2 | IP X3 and IP X4 tests |
- Ceiling - IP X1 / X2 - More than 10 mm |
112 | |
| 9.2 | Torque for fixing screws of covers |
- Instructions - Manufacturer - Table 4.1 |
113 | |
| 9.2f | Entry of test probes for IP 3X and 4X |
- IEC 60529 - Enclosure - Drain holes |
114 114.figure1 114.figure2 114.figure3 114.figure4 |
|
| 9.2 | IP ratings |
- Mounting board - 10 mm overhang - IP X3 / X4 |
255.03.LIP | |
| 9.2 | 9.2 |
- IP X3 / X4 - Quality of the lamp - Conformity |
267 | |
| 9.2 | Ingress protection / SELV |
- Water ingress - SELV parts - Fire risk |
268 | |
| 10 | Dielectric strength test on bushing |
- Class I - II - Bushings - Double insulated cable |
115 115.figure1 |
|
| 10.3 | Network described in IEC 60990 |
- IEC 60990 - IEC 60598-1 - Measuring network |
116 | |
| 11 | Distances inside a lamp |
- Heating tests - Creepage distances - Components |
117 | |
| 11 Annex M | Measurements of creepage distances and clearances |
- Maintenance - Live parts - Capacitor case |
118 | |
| 11.2 | Creepage distances and clearance |
- Annex “M” - Class I, II, III - SELV parts |
119 | |
| 11.2.1 | Creepage distances and clearances at a supply terminal |
- Lampholders - § 11.2.1 - Supply terminal |
121 | |
| 11.2.1 | Pendant luminaire with a "ceiling cone" |
- Mounting surface - Supply wires - Ceiling Cone |
120/03.m | |
| 12 | Endurance and thermal tests on appliances for purifying water using an UV lamp |
- Thermal tests - Abnormal conditions - Temperature of water flowing |
109/06 | |
| 12 | Heating tests for tungsten halogen lamps |
- Highest temperature - Warning notice - Luminaire |
122 | |
| 12 | Endurance and thermal tests |
- Clause 12 - IR - Time limited controls |
124 | |
| 12.1 | Temperature limits of the external parts (metal) of a fixed luminaire |
- Metal part - 70°C - Fixed luminaire |
280 280.figure1 |
|
| 12.3 | Interpretation regarding "mounting surface" / "illuminated surface" |
- Mounting surface - Illuminated surface - Abnormal operation |
125 | |
| 12.3.1 | Temperature decreasing during endurance test |
- Endurance test - Temperature - Below 25°C |
126 | |
| 12.4 | Luminaires recessed in the floor |
- Spot light - Halogen lamps - Parts intended to be touched |
127 | |
| 12.4 | Clarification of some luminaire parts |
- Handles, knobs - Hand lamps - § 3.3 -IEC 60598-1 |
128 | |
| 12.4 | Temperature measurement on replaceable glow starting device |
- Starter - IS 18 - Enec approval |
129 | |
| 12.4.1 | Temperature limit on terminal block |
- Terminal block - T marking - Clauses 13-14-15 |
130 | |
| 12.4.2 | Sleeve for earthing supply cable |
- Supply cable - Sleeve - Earthing conductor |
131 | |
| 12.5.1 | Abnormal operation condition |
- IP 00 transformer - IEC 61558-1 - Short-circuit test |
132 | |
| 12.5.1.4) | Luminaire inoperative after the test |
- Clauses 0.3-12.5) - SELV - Inoperative luminaire |
133 | |
| 12.5.1a)4) | Requirements for convertors |
- Transformers - Convertors - Requirements |
253.03.LIP | |
| 12.6 | “Laminated filter coil” |
- § 12.6 - Laminated filter coil - Small wound devices |
258.03.LIP | |
| 12.7 | Temperature extrapolated value |
- The graph - Fixation points - Ball pressure test |
135 | |
| 12.7.1 | Luminaires in thermoplastic material (fixing points) |
- Ballast - Constructive measures - § 4.15 a) / § 12.7.1 |
248 248.figure1 248.figure2 |
|
| 12.7.1 | Fault condition test |
- Normal operation - Mounting screws - Sub-clause 12.6 |
136 | |
| 13.2.1 | Ball pressure test on soft thermoplastic |
- Ball pressure test - Thermoplastic materials - Reinforced insulation |
137 | |
| 13.3.1 | Needle flame test / glow wire test |
- Needle flame - Glow wire (650°C) - Burning drops |
138 | |
| Annex A | Metallic paint |
- § 6.1 - IEC 60238 - Metallic paint |
139 | |
| Annex C | Self-ballasted lamps luminaires |
- Abnormal condition - 240 hours - Self ballasted lamps |
140 | |
| Annex C | Luminaires for M.H lamps |
- Rectifying effect - Declaration - Certification Body - Updated Table |
126/06 Table.rect.effect.zip |
|
| Annex D | Size of the test box (min.installation dimensions) |
- Instructions - Annex D - Requirement |
142 | |
| Annex D | Insulating material used around the test recess |
- Thermal conductivity - Tolerance - 0.04 W/mK |
143 | |
| Annex D | Test recesses in a luminaire with separate parts |
- Manufacturer instructions - Separating distances - Spacers |
287/04 | |